A Coldharbour company - serving Marietta, GA

Carrier Heat Pump Service Nationwide

Furnace & heatingFurnace & heating
AC repairAC repair
Heat pumpsHeat pumps
Ductless mini splitsDuctless mini splits
CarrierCarrier
TraneTrane
GoodmanGoodman
Every visit starts with

Seasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed

Your new heating and cooling system for as low as$119/month*On approved credit; ask for current terms

Diagnosis first, numbers second - you approve the repair price before a single part goes in.

Get your free estimate

Carrier Heat Pump Service: The Marietta Owner’s Guide

If your Carrier heat pump has stopped heating or cooling properly, most Marietta homes need a service call that runs between $150 and $650, with the majority of jobs landing around $220 to $380 once the failed part is identified and replaced. We carry common Carrier-compatible service parts on our trucks, so a lot of jobs in Marietta are done the same day you call. Here’s the typical story we hear: the system ran fine all summer, then one cool October morning it blows room-temperature air, or the outdoor unit hums but the fan won’t spin, or ice forms on the coil in July. That’s usually a single component, not the whole system, and it’s almost always repairable.

Call (762) 240-5599

Which Carrier Models This Applies To

We service the full Carrier heat pump lineup you’re likely to find in Marietta homes: the Infinity series (variable-speed, communicating systems), the Performance series (two-stage and single-stage), and the Comfort series (entry-level single-stage). The part that fails dictates the repair, not the series badge, but there’s a compatibility gotcha you should know: Carrier Infinity systems use communicating control boards and thermostats that talk to each other digitally. Swap in a generic board or the wrong revision and the system will throw a fault code and lock out. We match boards by the full model number, not just “it’s an Infinity.”

For most Carrier heat pump parts – contactors, capacitors, defrost control boards, reversing valves, fan motors – we recommend OEM Carrier parts when they’re available. Some aftermarket equivalents are fine; a universal capacitor rated within 5% of the original microfarad spec works without issue. But on communicating components, the reverse is true: we only install genuine Carrier revision-matched parts. The fastest way for you to help us is to snap a photo of the data plate on the outdoor unit. It lists the model, serial, and often the refrigerant type, which tells us exactly what’s on the truck before we roll.

Explore

Styles & brands we work with

AC repair
AC repair
Furnace & heating
Furnace & heating
Heat pumps
Heat pumps
Ductless mini splits
Ductless mini splits
Carrier
Carrier
Trane
Trane
Goodman
Goodman

Signs Your Carrier Heat Pump Is Failing

  • Outdoor unit hums but the fan doesn’t move. That’s usually a dead run capacitor, and it’s one of the most common heat pump failures we see in Marietta’s humid summers. The capacitor gives the compressor and fan motor the starting jolt they need; when it fails, you get a hum and a lot of heat building up inside the unit. Replace the capacitor quickly or the compressor can overheat and fail.
  • System cools in summer but won’t heat in winter. This points to a failed reversing valve or its solenoid coil. The reversing valve is the part that literally reverses the refrigerant flow to switch between heating and cooling. It’s a very Carrier-typical failure on units 10 years and older, and it’s not something you can diagnose by sound alone.
  • Unit trips the breaker repeatedly. Often this is a grounded compressor, loose wiring at the contactor, or a failing crankcase heater. In Marietta where thunderstorms and power surges are routine, we also see contactor points that have pitted from arcing. Once a contactor starts burning, the amp draw climbs and the breaker starts doing its job.
  • Ice builds up on the outdoor coil in winter (and won’t melt). Heat pumps frost over briefly, then run a defrost cycle to clear it. If the ice stays for hours or grows thick, the defrost control board or defrost thermostat has failed. On Carrier units, the board uses a timed cycle with a temperature sensor; when either half of that pair quits, the coil turns into an ice block and airflow drops to nothing.
  • Air blowing, but it’s never quite warm. Low refrigerant from a slow leak at a schrader valve or evaporator coil. Carrier heat pumps in Georgia see a lot of coil corrosion from the combination of humidity and airborne pollen, especially in older R-410A systems. A proper repair means finding and fixing the leak, not just topping off refrigerant.
Before & after

See the difference

Before - Recent ProjectBeforeAfter - Recent ProjectAfter
Recent Project
Before - Full RestorationBeforeAfter - Full RestorationAfter
Full Restoration
Before - Complete UpgradeBeforeAfter - Complete UpgradeAfter
Complete Upgrade

Replacement Cost & What’s Included

For Marietta homeowners, here’s what we quote before a single tool comes out:

  • Capacitor replacement: $150 – $280 installed, parts and labor
  • Contactor replacement: $150 – $260 installed
  • Defrost control board: $220 – $420 installed, OEM Carrier part
  • Thermostat or sensor: $120 – $250 installed
  • Reversing valve or solenoid coil: $350 – $650 installed, includes refrigerant recovery and recharge
  • Diagnostic call if you’re not sure what’s wrong: $80 – $120, applied toward the repair if you proceed

Every one of these numbers is a written price, handed to you before the work starts. It doesn’t change at the door. What drives the range is mostly the specific part and whether the system needs refrigerant recovery (for reversing valves) versus a simple electrical swap. Each repair includes the 365-Day Done Right Promise, so if the same part fails again within a year, the return visit and correction cost you nothing. That’s on paper, not a handshake.

DIY or Call Us?

Here’s the honest split. You can safely check a few things yourself: confirm the thermostat is set correctly and the breakers at the panel and the outdoor disconnect box haven’t tripped. That’s it for safety. Heat pumps carry 240 volts at the outdoor unit even when the thermostat is off, and the dual-run capacitor holds a charge that can knock you flat long after power is cut. The danger zone is the contactor, capacitor, and any wiring inside the electrical service panel of the unit. If you open that panel without discharging the capacitor properly, you’re risking a serious, potentially fatal shock. We’d rather you call us for anything beyond flipping a breaker back on. You can reach us at (762) 240-5599; if you describe the symptom, we’ll tell you honestly whether it’s a quick truck part or a bigger diagnosis.

FAQs

Need HVAC help in Marietta? Licensed & insured · 30-60 min response · free estimates
Call (762) 240-5599
Local Service Coverage

Request a Free Estimate in Marietta

Tell us what you need - Cold Harbour Heating and Air Marietta responds fast. No obligation.

By requesting your free estimate, you agree to our Privacy Policy and agree to be contacted through phone, text, or email concerning your request, including by the partner businesses that may perform the service.

Prefer to text? Text Us
Call Now - 24/7 Dispatch